Following are the difference between shunt capacitor and series inductor filter:
Parameter | Shunt Capacitor | Series Inductor |
---|---|---|
Place of filter | Across the load | In series with load |
Useful in | Reducing ripple in load voltage | Reducing ripple in load current |
Lowest ripple in load voltage at | No load or light loads | Heavy loads |
Suitable for | Light load application | Heavy load application |
Surge current | Very high and must be controlled | Low and need not be control |
Ripple factor | R = 1/ 4√3 FCR | R = R/3√2 WL |
Size of filter | Small and compact | Bulky |